,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,High-Voltage High-Vacuum Rectifier Tubes,High-Voltage,High-Vacuum,Rectifier,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">

V1-0,1/30

RECTIFIER TUBE

The V1-0,1/30 rectifier tube provides rectification of high-voltage alternating current

GENERAL
Cathode: directly heated, carbonized tungsten.
Envelope: glass.
Height: at most 129 mm.
Diameter: at most 59 mm.
Mass: at most 120 g

v1-0,1[30(1)00021.jpg

OPERATING ENVIRONMENTAL CONDITIONS
Vibration loads:
frequencies. Hz 5-1,000
acceleration, m/s² 98
Multiple impacts at impact duration up to 80 ms with acceleration, m/s² 343
Ambient temperature, °C -60 to + 70
Relative humidity at up to +40 °C. % 98

BASIC DATA
Electrical Parameters
Filament voltage, V 5
Filament current (half-cathode), A 4.75-5.25
Peak emission current (at anode voltage 1 kV), mA, at least 800
Emission current (at anode voltage 300 V), mA, at least 290
Peak emission current over 500 h of service, mA, at least 500

Limit Operating Values
Filament voltage, V 4.75-5.25
Reverse voltage, peak value, kV 30
Anode current, peak value, mA 400
Anode dissipation, W 60

v1-0,1[30(2)00031.jpg
Standard Anode Characteristic Curves:
Uf = 5V; timp = µs; pulse frequency 200 Hz

v1-0,1[30(2)00032.jpg
Standard Cathode Emission Characteristic Curves