,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,High-Voltage High-Vacuum Rectifier Tubes,High-Voltage,High-Vacuum,Rectifier,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">

V1-0,1/40

RECTIFIER TUBE

The V1-0,1/40 rectifier tube is used in rectifier circuits of RF equipment

GENERAL
Cathode: directly heated, carbonized thoriated tungsten.
Envelope: glass, with base.
Height: at most 205 mm.
Diameter: at most 53 mm.
Mass: 150g

v1-0,1[40(1)00031.jpg

OPERATING ENVIRONMENTAL CONDITIONS
Single impacts at impact duration up to 10 ms with acceleration, m/s² 50
Ambient temperature, °C -60 to +70
Relative humidity at up to +40 °C, % 98

BASIC DATA
Electrical Parameters
Filament voltage, V 5
Filament current, A 5.5-6.5
Emission current, mA:
peak (at filament voltage 5.5 V, peak anode voltage 4 kV, pulse duration 5-10 µs, pulse frequency 50 Hz) 2,000
at filament voltage 3V 30
Anode current (at anode 200 V), mA, at least 75
Emission current (at filament voltage 3 V), over 500 h of service, mA, at least 15

v1-0,1[40(2)00041.jpg