,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Transmitting Pulse Tubes,Transmitting,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">

GI-15B-1
(GI-150-1)

TRIODE

The GI-15B-1 (GI-150-1) triode is used as a RF oscillator and amplifier operating in continuous-wave or pulsed mode with anode modulation.

The triode is available in two variants differing in the type of cooling: the GI-15B-1 with a heat sink for forced air cooling and the GI-150-1 with no heat sink.

GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: metal-ceramic.
Height: 88.5 mm with heat sink, 79.7 mm with no heat sink.
Diameter: at most 45 mm with heat sink, 26.3 mm with no heat sink.
Mass: at most 120 g with heat sink, 60 g with no heat sink.

gi-15b-1(gi-150-1)(1)00031.jpg
gi-15b-1(gi-150-1)(1)00032.jpg
KP - cathode and heater; P - heater; C - grid; A - anode

OPERATING ENVIRONMENTAL CONDITIONS
Vibration loads:
frequencies, Hz 1-200
acceleration, m/s² 49
Multiple impacts with acceleration, m/s² 392
Ambient temperature, °C -10 to +55
Relative humidity at up to +25 °C, % 98

BASIC DATA
Electrical Parameters
Heater voltage, V 12.6
Heater current, A 0.75-0.88
Mutual conductance (at anode voltage 400 V, grid voltage change 0.5 V, anode current 15 mA), mA/V, at least 8
Negative grid voltage (at anode voltage 400 V, anode current 15 mA), V 4-1.5
Interelectrode capacitance, pF:
input 9-12
transfer 2-3
Warm up time, s, at most 60
Output power, W, at least 8.5
Output power over 1200 h of service, W, at least 7

Limit Operating Values
Heater voltage, V 12-13.2
Anode voltage, kV:
in pulsed operation (with pulse duration at most 5 µs) 4
DC 0.8
Cathode current, A:
r.m.s. 0.15
in pulsed operation (with pulse duration at most 5 µs) 3.5
Dissipation, W:
anode, with forced cooling 80
grid 2
Wavelength (in pulsed operation), cm, at least 8.5
Cathode heating time, s, at least 45
Temperature, °C:
anode 200
leads of grid and cathode 120
cathode lead (after operation for at most 10 min) 140
Resistance in grid circuit, kOm 10